Biasi Rinnova Adaptive 30 S Gas Condensing Boiler suitable for providing heating service for a 200 m² home, and Hot Water for a home with a Bathroom and a Toilet. Unlike traditional boilers, the Biasi Rinnova Adaptive condensing boiler allows energy to be recovered by condensing the water vapor contained in the exhaust fumes; That is, for the same heat produced, it consumes less gas and the smoke outlet also contains fewer substances harmful to the environment.
CHARACTERISTICS
- Nominal heating/domestic hot water flow rate kW: 26.0/31.0
- Minimum heating output / DHW kW: 3.8/3.8
- Maximum useful power heating/sanitary 60°/80°C * kW: 25.6/30.6
- Minimum useful power heating/sanitary 60°/80°C * kW: 3.6/3.6
- Maximum useful power heating / DHW 30 ° / 50 ° C ** kW: 28.3/33.7
- Minimum useful power heating / sanitary 30 ° / 50 ° C ** kW:4.0/4.0
- Amount of condensate in Q.nominal 30 ° / 50 ° C (in heating) ** l / h : 5
- Condensation amount at Q.min. 30°/50°C (in heating) ** l/h: 0.6
- PhD condensate pH: 4.0
- Nominal performance 60°/80°C * %: 98.6
- Performance . min. 60°/80°C * %: 94.5
- Performance . nominal 30°/50°C **%: 108.7
- Performance . min. 30°/50°C **%: 105.8
- Performance . at 30% load ** % : 109.7
- Energy efficiency ηs %: 94
- Thermal losses in the chimney with the burner in operation Pf (%): 1.2
- Thermal losses in the chimney with burner off ΔT 50 ° C Pfbs (%) : 0.2
- Thermal losses to the environment through the casing with the burner in operation Pd (%) : 0.9
- NOx class: 6
- Weighted NOx [Hs] *** mg/kWh: 31
- Minimum/maximum heating temperature ****°C: 25/80
- Minimum/maximum heating pressure bar: 0.3/3
- Available head heating (at 1000 l/h) mbar: 320
- Expansion vessel capacity (total / useful) L: 7
- Minimum/maximum temperature of domestic hot water ° C: 35/55
- Minimum / maximum sanitary pressure bar: 0.3 / 10
- Maximum flow rate (ΔT = 25 K) / (ΔT = 35 K) l / min : 18.3/12.8
- Specific sanitary flow rate (ΔT = 30 K) ***** l / min: 15.2
- Voltage/power at rated heat input V~/W: 230/96
- Power at minimum heat input W: 55
- Power at rest (standby) W: 3
- Protection degree: IPX5D
- Minimum/maximum flue gas temperature #°C: 41/78
- Minimum/maximum smoke mass flow # kg/sec: 0.0044/0.0144
- Minimum/maximum air mass flow rate # kg/sec: 0.0044/ 0.0139
- Max. coaxial smoke discharge length (Ø 60/100 mm / Ø 80/125 mm) meter: 10/15
- Max. divided smoke outlet length (Ø 80 + 80 mm) meter: 40
- Height x Width x Depth mm: 700 x 400 x 300
- Weight kg: 36
- Boiler water content L: 2.5